Our precision temperature, humidity, and altitude chambers provide accurate environmental simulations for product durability testing. These chambers help ensure your products meet rigorous industry standards through comprehensive testing capabilities.
Model | JQTA-225 | JQTA-504 | JQTA-1000 | JQTA-1700 | JQTA-3400 |
---|---|---|---|---|---|
Inner Size (cm) | 50×75×65 | 80×70×90 | 100×100×100 | 195×315×516 | 407×210×407 |
Volume (L) | 225L | 504L | 1000L | 1700L | 3400L |
Temperature Range | L type: -40℃ to 150℃ S type: -70℃ to 150℃ (customizable) |
||||
Humidity Range | 20% to 98% RH | ||||
Temperature Fluctuation | ±0.5℃ | ||||
Temperature Variation in Space | No-load at atmospheric pressure ±3℃ (≥100℃), ±2℃ (≤100℃) | ||||
Cooling/Rising Rate | 0.7℃ to 1℃/min | ||||
Exterior Material | 1.5mm Electrolytic plate with Electrostatic painting | ||||
Interior Material | Stainless steel plate SUS304 |
Performance data refers to an operating room temperature of +26°C, 415 V/50 Hz nominal voltage, without test specimen and without accessories.
Sound Pressure Level: Measured in free-field environments at 1 meter height from floor and 1 meter distance from equipment surface.