Proper maintenance of a Thermal Shock Chamber is essential to ensure its optimal performance, accuracy, and longevity. Regular upkeep helps prevent malfunctions, ensures reliable test results, and extends the lifespan of the equipment.
- Visual Checks: Regularly inspect the chamber for any signs of wear, corrosion, or damage.
- Seals and Gaskets: Check door seals and gaskets for cracks or deformation to maintain proper insulation and prevent leaks.
- Transfer Mechanism: Ensure the specimen transfer system moves smoothly without obstructions or unusual noises.
- Interior Cleaning: Keep the chamber interior free from dust, debris, and corrosion. Use mild, non-abrasive cleaning agents.
- Cooling and Heating Elements: Remove dust or dirt from heating elements and cooling coils to ensure efficient operation.
- Air Filters: Clean or replace air filters periodically to maintain airflow and temperature uniformity.
- Temperature Calibration: Regularly calibrate temperature sensors and controllers against standard reference instruments.
- Cycle Verification: Verify the accuracy of temperature cycling profiles and transfer times.
- Data Logging: Maintain records of calibration and maintenance activities for compliance and troubleshooting.
- Lubrication: Lubricate moving parts, such as transfer arms and hinges, as per manufacturer recommendations.
- Electrical Components: Inspect wiring, relays, and sensors for signs of wear or damage. Replace faulty components promptly.
- Control Panel: Ensure the control interface is functioning correctly and buttons or touchscreens are responsive.
| Frequency | Tasks |
|---|---|
| Weekly | Visual inspection, cleaning of interior and filters |
| Monthly | Calibration checks, mechanical inspections |
| Quarterly | Detailed electrical inspection, lubrication, transfer system check |
| Annually | Comprehensive calibration, part replacement as needed, system audit |
- Always follow the manufacturer's maintenance manual and guidelines.
- Use genuine spare parts and accessories.
- Keep detailed records of all maintenance activities for reference and compliance.
- Train operators on proper usage and basic maintenance procedures.
| Model | JQTS2-50 | JQTS2-80 | JQTS2-100 | JQTS2-150 | JQTS2-225 | JQTS2-408 |
|---|---|---|---|---|---|---|
| Inner size W*D*H(cm) | 35*32*40 | 50*40*40 | 50*50*40 | 65*50*46 | 65*70*50 | 85*80*60 |
| Outer size W*D*H(cm) | 125*160*185 | 135*170*185 | 140*185*190 | 160*190*205 | 160*230*210 | 180*250*230 |
| Capacity(L) | 50L | 80L | 100L | 150L | 225L | 408L |
| Weight(kg) N.W | 800 | 900 | 950 | 1050 | 1250 | 1450 |
- High Temp.->Low Temp.
- Low Temp ->High Temp.
- Normal Temp ->High Temp. ->Normal Temp. ->Low Temp.
- Normal Temp ->High Temp. ->Normal Temp. ->Low Temp

Product Highlights
Maintenance of Two Zone Thermal Shock Test Chamber Product Specifications Model: JQTS-100 Temperature Range: -40°C/-55°C/-65°C~+150°C Maintenance of Thermal Shock Chamber Proper maintenance of a Thermal Shock Chamber is essential to ensure its optimal performance, accuracy, and longevity. Regular ...
Industrial Vibration Table For Automotive Electronics And Construction Industries
Industrial Vibration Table Designed for rigorous vibration resistance testing, this industrial vibration table is widely used across automotive, electronics, and construction industries to ensure product durability under transport conditions. Key Specifications Frequency: 2000Hz Sine force: 50kN / 5000kg Random force: 50kN / 5000kg Shock force: 98kN / 9800kg / 9918lbf Channel options: 2/4/8/16 Maximum acceleration: 100g Maximum displacement: 100mm (4") / 76mm (3") / 51mm (2")
Digital Control Hydraulic Shock Test System For ISTA Package Test
Hydraulic Shock Test System for ISTA Package Test IS Shock Test Machine The Shock Test Machine is a high-acceleration testing system specifically designed to meet military industry and home appliance testing requirements. Utilizing drop principle technology with air pressure reverse thrust or spring energy storage, it achieves various acceleration levels through adjustable inflation pressure. For higher accelerations, the system includes a waveform amplifier. This automatic
AC380V 50Hz Temperature Humidity Altitude Chamber environmental testing chamber
Reliable Temperature, Humidity, & Altitude Chamber for Quality Testing The Temperature, Humidity, and Altitude Chamber is a state-of-the-art testing solution designed to simulate a variety of environmental conditions for research, product testing, and quality control. These chambers offer precise control over temperature, humidity, and altitude levels, making them ideal for industries such as aerospace, automotive, electronics, and pharmaceuticals. Key Features Programmable
2000Hz Horizontal Slip Table Vibration Testing Humidity Range ≤90%
Slip Table for Vibration Shaker System A slip table in vibration testing is an auxiliary table used with a vibration exciter (shaker) to transmit motion in the horizontal direction. It's essential for testing specimens in a horizontal orientation, particularly when the specimen's orientation must be maintained throughout the test. Slip tables also enable testing of large and heavy specimens that might exceed the capacity of the shaker's vertical table.Key Functions and
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.