Maintenance of Two Zone Thermal Shock Test Chamber
Product Specifications
Model: JQTS-100
Temperature Range: -40°C/-55°C/-65°C~+150°C
Maintenance of Thermal Shock Chamber

Proper maintenance of a Thermal Shock Chamber is essential to ensure its optimal performance, accuracy, and longevity. Regular upkeep helps prevent malfunctions, ensures reliable test results, and extends the lifespan of the equipment.

1. Routine Inspection
  • Visual Checks: Regularly inspect the chamber for any signs of wear, corrosion, or damage.
  • Seals and Gaskets: Check door seals and gaskets for cracks or deformation to maintain proper insulation and prevent leaks.
  • Transfer Mechanism: Ensure the specimen transfer system moves smoothly without obstructions or unusual noises.
2. Cleaning
  • Interior Cleaning: Keep the chamber interior free from dust, debris, and corrosion. Use mild, non-abrasive cleaning agents.
  • Cooling and Heating Elements: Remove dust or dirt from heating elements and cooling coils to ensure efficient operation.
  • Air Filters: Clean or replace air filters periodically to maintain airflow and temperature uniformity.
3. Calibration and Testing
  • Temperature Calibration: Regularly calibrate temperature sensors and controllers against standard reference instruments.
  • Cycle Verification: Verify the accuracy of temperature cycling profiles and transfer times.
  • Data Logging: Maintain records of calibration and maintenance activities for compliance and troubleshooting.
4. Mechanical and Electrical Checks
  • Lubrication: Lubricate moving parts, such as transfer arms and hinges, as per manufacturer recommendations.
  • Electrical Components: Inspect wiring, relays, and sensors for signs of wear or damage. Replace faulty components promptly.
  • Control Panel: Ensure the control interface is functioning correctly and buttons or touchscreens are responsive.
5. Preventive Maintenance Schedule
Frequency Tasks
Weekly Visual inspection, cleaning of interior and filters
Monthly Calibration checks, mechanical inspections
Quarterly Detailed electrical inspection, lubrication, transfer system check
Annually Comprehensive calibration, part replacement as needed, system audit
 
Additional Tips:
  • Always follow the manufacturer's maintenance manual and guidelines.
  • Use genuine spare parts and accessories.
  • Keep detailed records of all maintenance activities for reference and compliance.
  • Train operators on proper usage and basic maintenance procedures.
Technical Specifications
Model JQTS2-50 JQTS2-80 JQTS2-100 JQTS2-150 JQTS2-225 JQTS2-408
Inner size W*D*H(cm) 35*32*40 50*40*40 50*50*40 65*50*46 65*70*50 85*80*60
Outer size W*D*H(cm) 125*160*185 135*170*185 140*185*190 160*190*205 160*230*210 180*250*230
Capacity(L) 50L 80L 100L 150L 225L 408L
Weight(kg) N.W 800 900 950 1050 1250 1450
Performance Specifications
Temp. Shock Range: A:-40℃~180℃ B:-55℃~180℃ C:-65℃~180℃
Shock type:
  1. High Temp.->Low Temp.
  2. Low Temp ->High Temp.
  3. Normal Temp ->High Temp. ->Normal Temp. ->Low Temp.
  4. Normal Temp ->High Temp. ->Normal Temp. ->Low Temp