logo
Quality 1000L High And Low Temp Humidity Chamber PWM Control -70 Degree factory
<
Quality 1000L High And Low Temp Humidity Chamber PWM Control -70 Degree factory
Quality 1000L High And Low Temp Humidity Chamber PWM Control -70 Degree factory
Quality 1000L High And Low Temp Humidity Chamber PWM Control -70 Degree factory
Quality 1000L High And Low Temp Humidity Chamber PWM Control -70 Degree factory
>

1000L High And Low Temp Humidity Chamber PWM Control -70 Degree

Brand Name: Jianqiao
Model Number: JQTH-1000
Place of Origin: China
Certification: CE
Minimum Order Quantity: 1
Supply Ability: 300 sets /year

Product Details


Power Supply: AC 220V Or AC380V 50Hz 3 PHASE With Ground Wire Working Conditions: RT To 35℃
Control Method: PWM Control Temp Uniformity: ±2℃(No-load)
Temp Fluctuation: ±0.5℃(No-load) Temp Range: Model S:-70°C~+150°C , Model L: -40°C~+150°C Or Customized.
Highlight

1000L Temp Humidity Chamber

,

Temp Humidity Chamber PWM Control

Product Description

Maintenance method


The constant temperature and humidity test chamber has been widely used in the fields of electronics industry, national defense technology, chemical industry, mechanical manufacturing, aerospace and aviation. The constant temperature and humidity test chambers produced by us adopt the perfect design from Germany, which is at the forefront of the world.


Then, how is the constant temperature and humidity test chamber maintained and cleaned during daily work?


1. Cleaning and maintenance of the interior and exterior of the constant temperature and humidity test chamber
(1) Before operating the constant temperature and humidity test chamber, the internal impurities should be removed first.
(2) The distribution room should be cleaned at least once a year.
Above, during cleaning, you can use a vacuum cleaner to remove the dust in the room.
(3) The exterior of the box also needs to be cleaned at least once a year. When cleaning, simply wipe it with soapy water.

 


2. Inspection and maintenance of the humidifier in the constant temperature and humidity test chamber: The stored water in the humidifier should be replaced monthly to ensure clean water quality. The water collection tray should be cleaned once a month to ensure smooth water flow.


3. Inspection of the over-temperature protector in the constant temperature and humidity test chamber: When the test chamber is running, the maximum set value of the over-temperature protection should be increased by 20℃ to 30℃. When the temperature in the test chamber rises to the set point of the over-temperature protection, the power supply of the heater will be cut off, and the "OVERHEAT" warning light will be on but the fan will still be running. If it runs for a long time and no one is watching, please make sure to check the over-temperature protector before starting the operation to ensure it is set properly [the setting of the wet bulb over-temperature protector is 120℃].


4. Dust removal from the condenser of the constant temperature and humidity test chamber: The condenser should be maintained monthly for regular cleaning. Use a vacuum cleaner to remove the dust attached to the cooling mesh of the condenser or use high-pressure air to blow off the dust.


5. Replacement of the wet bulb test cloth in the constant temperature and humidity test chamber: When the surface of the test cloth is not clean or becomes hard, or after temperature control, before continuing the temperature and humidity ball control, the test cloth must be replaced. The test cloth should be replaced approximately every three months. When replacing, use a clean cloth to wipe the temperature sensor. When replacing the new test cloth, clean it thoroughly.


6. Inspection and adjustment of the wet bulb water level in the constant temperature and humidity test chamber: The water level of the water collection tank should not be too high, as it may cause water to overflow from the water collection tank or too low, causing abnormal water absorption by the wet bulb test cloth and affecting the accuracy of the wet bulb. The water level should be approximately six-fifths full. The adjustment of the water level of the water collection tank can be done by adjusting the height of the water collection box.


7. If the constant temperature and humidity test chamber is left idle for a long time, it should be powered on monthly for regular maintenance for at least 1 hour.

 

         Model   

JQTH-100

JQTH-150

JQTH-225

JQTH-408

JQTH-800

JQTH-1000

JQTH-1200

JQTH-1500

Volume (L)

100L

150L

225L

408L

800L

1000L

1200L

1500L

 Inner size (cm)

W

50

50

70

70

100

100

150

150

D

40

50

46

75

80

100

80

100

H

50

60

70

80

100

100

100

100

 Outer size (cm)

W

70

70

90

90

120

120

200

200

D

125

135

157

188

185

205

135

155

H

157

167

185

195

215

215

215

215

Temp range

Model S:-70°C~+150°C  ,   Model L: -40°C~+150°C or customized.

Exterior material

  Standard 1.5mm Electrolytic plate with Electrostatic  painting

 Interior material

Matte Stainless steel plate SUS 304

Insulation material

Rigid Polyurethane  Foam and Glass Fiber Wool

Refreigeration system

Hermetric Compressor ,Cascsde Refrigeration CFC free refrigeration system ,
HFC-R404A/HFC-23/HFC-R449 /HFC-507

Control method

PWM control

 Working conditions

RT to 35

Humidity range

10 % to 98% RH 10 %~ 98% RH

Temp fluctuation

      ±0.5(No-load)

Temp  uniformity

      ±2(No-load)

Temp cooling rate

+150°C ~-70°C ,0.8°C~ 1/min (Non-Linear)

Temp rising rate

  -70°C~+150°C , 1°C~3/ min (Non-Linear)

Controller

TW DELTA PLC,7 "color touch screen control Chinese,English,Russian menu
Operation Model :Setting Fix /Program

Standard Accessories

Observation Window *1,Cable Port (50mm*2),Shelves*2 ,Chamber lamp*1,Power cable 2m

Safety device

No-Fuse Breaker,Over -pressure,Over-load and Over-current protector for compressor ,Over-Temp,Protector Over-voltage coolant protector ,Overload protector for fan, Dry heat protector and Fault warning system ,
short of water protector

Configuration interface

With USB , WLAN, RS232 or R485 port , APP function is optional

Power

5.5KW

6KW

8.5KW

9KW

13.5KW

15KW

17KW

18KW

Weight (kg)

300

360

430

530

780

890

1100

1380

Power supply

AC 220V or  AC380V 50Hz 3 PHASE ,Ground wire

 

 

1000L High And Low Temp Humidity Chamber PWM Control -70 Degree 01000L High And Low Temp Humidity Chamber PWM Control -70 Degree 11000L High And Low Temp Humidity Chamber PWM Control -70 Degree 21000L High And Low Temp Humidity Chamber PWM Control -70 Degree 3

Product Highlights

Maintenance method The constant temperature and humidity test chamber has been widely used in the fields of electronics industry, national defense technology, chemical industry, mechanical manufacturing, aerospace and aviation. The constant temperature and humidity test chambers produced by us adopt ...

Related Products
Quality Industrial Vibration Table For Automotive Electronics And Construction Industries factory

Industrial Vibration Table For Automotive Electronics And Construction Industries

Industrial Vibration Table Designed for rigorous vibration resistance testing, this industrial vibration table is widely used across automotive, electronics, and construction industries to ensure product durability under transport conditions. Key Specifications Frequency: 2000Hz Sine force: 50kN / 5000kg Random force: 50kN / 5000kg Shock force: 98kN / 9800kg / 9918lbf Channel options: 2/4/8/16 Maximum acceleration: 100g Maximum displacement: 100mm (4") / 76mm (3") / 51mm (2")

Quality Digital Control Hydraulic Shock Test System For ISTA Package Test factory

Digital Control Hydraulic Shock Test System For ISTA Package Test

Hydraulic Shock Test System for ISTA Package Test IS Shock Test Machine The Shock Test Machine is a high-acceleration testing system specifically designed to meet military industry and home appliance testing requirements. Utilizing drop principle technology with air pressure reverse thrust or spring energy storage, it achieves various acceleration levels through adjustable inflation pressure. For higher accelerations, the system includes a waveform amplifier. This automatic

Quality AC380V 50Hz Temperature Humidity Altitude Chamber environmental testing chamber factory

AC380V 50Hz Temperature Humidity Altitude Chamber environmental testing chamber

Reliable Temperature, Humidity, & Altitude Chamber for Quality Testing The Temperature, Humidity, and Altitude Chamber is a state-of-the-art testing solution designed to simulate a variety of environmental conditions for research, product testing, and quality control. These chambers offer precise control over temperature, humidity, and altitude levels, making them ideal for industries such as aerospace, automotive, electronics, and pharmaceuticals. Key Features Programmable

Quality 2000Hz Horizontal Slip Table Vibration Testing Humidity Range ≤90% factory

2000Hz Horizontal Slip Table Vibration Testing Humidity Range ≤90%

Slip Table for Vibration Shaker System A slip table in vibration testing is an auxiliary table used with a vibration exciter (shaker) to transmit motion in the horizontal direction. It's essential for testing specimens in a horizontal orientation, particularly when the specimen's orientation must be maintained throughout the test. Slip tables also enable testing of large and heavy specimens that might exceed the capacity of the shaker's vertical table.Key Functions and

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.