logo
Quality Solid Environmental Walk In And Drive In Chambers For Stability Testing And Storage factory
<
Quality Solid Environmental Walk In And Drive In Chambers For Stability Testing And Storage factory
>

Solid Environmental Walk In And Drive In Chambers For Stability Testing And Storage

Brand Name: Jianqiao
Model Number: JQWI-2000
Place of Origin: CHINA
Certification: CE
Minimum Order Quantity: 1
Supply Ability: 300

Product Details


Humidity Range: 20 % To 98% RH Weight(kg): Subject To The Actual Weight
Interior Material: Stainless Steel Plate Sus304 Temp.Range: -70℃/-40℃~85℃/120℃/150℃/180℃ Customized
Temp Fluctuation: ±0.5℃ Design: Modular
Highlight

Environmental Drive In Chambers

,

Solid Drive In Chambers

,

Environmental Walk In Chambers

Product Description

Modular Penalized Solid Environmental Walk-In and Drive-In Chambers

Our walk-in temperature and humidity testing chambers provide highly precise and reproducible conditions for climatic and temperature testing across multiple industries.

Common Applications
  • Environmental testing
  • Electronics, automotive, aerospace
  • Building materials, military equipment
  • Materials research and quality control
  • Production facilities
Key Features
  • Advanced climate control technology
  • Aerodynamically optimized interior for uniform conditions
  • Configurable testing programs with automatic operation
  • Durable stainless steel interior for easy cleaning
  • Compliant with EN, IEC, DIN, ISO, NP and UNE standards
  • Non-polluting construction and cooling system
Solid Environmental Walk In And Drive In Chambers For Stability Testing And Storage 0
Installation Requirements
Standard Air-Cooled System
¾" demineralized water supply
50mm water drain at floor level
Electrical supply: 400VAC, 50Hz, 80A / 3-Phase + Neutral + Ground
Electrical protection: Circuit breaker 3 x 80A + N with 300mA differential
Water-Cooled System
Water flow (at 25°C): up to 5000 litres/hour
Intake pressure: 2 to 5 bar
Water entry/exit pipe: 1" or 28mm
Recommended water entry temperature: 18°C
Technical Specifications
Temperature sensors: PT 100 Class A (fixed and movable)
Heating: Stainless steel electric heaters
Cooling: Scroll compressor group with high efficiency
Thermal security: Safety thermostats with auto-stop function
Humidity control: Multiple sensor technologies available
Construction: AISI 304 stainless steel interior with SECC steel exterior
Door: Double silicone joints with anti-condensation heating
Standard Inclusions
  • RJ45 Ethernet port
  • Ø 100 mm lateral entry port
  • 6 casters for leveling and parking
  • English instruction manual
  • 1 year warranty
Solid Environmental Walk In And Drive In Chambers For Stability Testing And Storage 1
HMI Controller Features
  • Programmable PLC with color touch-screen
  • 0.1°C temperature and 0.1% humidity resolution
  • 50 programs with 50 segments each
  • Automatic restart after power failure
  • Remote access via VNC server
  • Real-time monitoring and data recording
Model Specifications
Model JQWI-08 JQWI-12 JQWI-16 JQWI-25 JQWI-34 JQWI-40
Internal Dimensions (cm) 200×200×200 200×300×200 220×350×210 300×400×210 340×480×220 400×500×220
Volume 8.0 m³ 12 m³ 16 m³ 25 m³ 34 m³ 40 m³
Temperature Range -70°C/-40°C to +150°C/+180°C (customizable)
Humidity Range 20% to 98% RH
Power Supply AC 380V @ 50Hz
Solid Environmental Walk In And Drive In Chambers For Stability Testing And Storage 2

Product Highlights

Modular Penalized Solid Environmental Walk-In and Drive-In Chambers Our walk-in temperature and humidity testing chambers provide highly precise and reproducible conditions for climatic and temperature testing across multiple industries. Common Applications Environmental testing Electronics, ...

Related Products
Quality Industrial Vibration Table For Automotive Electronics And Construction Industries factory

Industrial Vibration Table For Automotive Electronics And Construction Industries

Industrial Vibration Table Designed for rigorous vibration resistance testing, this industrial vibration table is widely used across automotive, electronics, and construction industries to ensure product durability under transport conditions. Key Specifications Frequency: 2000Hz Sine force: 50kN / 5000kg Random force: 50kN / 5000kg Shock force: 98kN / 9800kg / 9918lbf Channel options: 2/4/8/16 Maximum acceleration: 100g Maximum displacement: 100mm (4") / 76mm (3") / 51mm (2")

Quality Digital Control Hydraulic Shock Test System For ISTA Package Test factory

Digital Control Hydraulic Shock Test System For ISTA Package Test

Hydraulic Shock Test System for ISTA Package Test IS Shock Test Machine The Shock Test Machine is a high-acceleration testing system specifically designed to meet military industry and home appliance testing requirements. Utilizing drop principle technology with air pressure reverse thrust or spring energy storage, it achieves various acceleration levels through adjustable inflation pressure. For higher accelerations, the system includes a waveform amplifier. This automatic

Quality AC380V 50Hz Temperature Humidity Altitude Chamber environmental testing chamber factory

AC380V 50Hz Temperature Humidity Altitude Chamber environmental testing chamber

Reliable Temperature, Humidity, & Altitude Chamber for Quality Testing The Temperature, Humidity, and Altitude Chamber is a state-of-the-art testing solution designed to simulate a variety of environmental conditions for research, product testing, and quality control. These chambers offer precise control over temperature, humidity, and altitude levels, making them ideal for industries such as aerospace, automotive, electronics, and pharmaceuticals. Key Features Programmable

Quality 2000Hz Horizontal Slip Table Vibration Testing Humidity Range ≤90% factory

2000Hz Horizontal Slip Table Vibration Testing Humidity Range ≤90%

Slip Table for Vibration Shaker System A slip table in vibration testing is an auxiliary table used with a vibration exciter (shaker) to transmit motion in the horizontal direction. It's essential for testing specimens in a horizontal orientation, particularly when the specimen's orientation must be maintained throughout the test. Slip tables also enable testing of large and heavy specimens that might exceed the capacity of the shaker's vertical table.Key Functions and

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.