The Thermal abuse test chamber is based on the requirements of the test standards such as UL1642 and IEC62133. After the battery is fully charged, the battery is placed in the test chamber. The test chamber is heated at a temperature rise rate of (5 ± 2) ° C / min, and the temperature is constant after the temperature in the chamber reaches 130 ° C ± 2 ° C for 30 min. The battery should not ignite and not explode.
Single battery safety test:
The heating test:
a) The rechargeable battery is charged according to the method of 6.1.3.
b) The single battery is placed in the temperature chamber.
For lithium ion batteries, the temperature chamber is raised from RT to 130 °C ± 2 °C at a rate of 5 ° C / min,
and the heating is stopped after maintaining this temperature for 30 min;
For metal cyanide nickel batteries, the temperature chamber is heating at a rate of 5 ° C / min
The temperature was raised from RT to 85 ° C ± 2 ° C, and the temperature was stopped after 2 h.
c) observe 1h
Battery module safety test:
The battery module battery is charged according to the method of 6.1.4;
a) For the lithium ion battery, the temperature box is raised from room temperature to 130 °C ± 2 °C at a rate of 5 ° C / min,
and the heating is stopped after maintaining the temperature for 30 min;
b) For the cyanide nickel battery, the temperature box was raised from room temperature to 85 °C ± 2 °C at a rate of 5 ° C / min,
and the heating was stopped after maintaining this temperature for 2 h.
c) observe 1h
Model |
RLY-1000A |
Temperature control method |
Touch screen |
Temperature range |
Room temperature (or ambient temperature) +10~200°C |
Temperature display accuracy |
±0.1℃ |
Temperature uniformity |
±2℃ |
Chamber inner size (W·D·H)
|
1000*1000*1000mm( customized ) |
Chamber outter size (W·D·H)
|
1400*1300*1840mm |
Heating rate |
(5±2)℃/min Nonlinear no-load |
Temperature Controller |
Delta touch screen series temperature controller |
Chamber Inner material |
stainless steel |
Chamber Outer material |
Cold rolled steel sheet baking treatment |
Timing function |
Touch screen display, freely set from 0~9999h/m/s |
Insulation material |
High efficiency compression insulation cotton |
Exhaust flue |
Fin design allows for adjustable air volume |
Thermal insulation device |
Fuseless switch, over temperature protection switch, porcelain fuse |
Safety equipment |
The first over temperature alarm, MCCB overload protection, etc. |
Control System |
When the temperature is up, the time is up, the buzzer stops. |
Air circulation system |
Convection air circulation system |
Power |
AC220V±10%,50/60Hz |